{"product_id":"vertiv-liebert-gxt-mt-cx-gxt-3000mtplusc230-ups-3000va-2700w-online-double-conversion-pure-sinewave-0-99-input-power-factor","title":"Vertiv Liebert GXT MT+ CX GXT-3000MTPLUSC230 UPS | 3000VA \/ 2700W | Online Double-Conversion | Pure Sinewave | 0.99 Input Power Factor | 90% Efficiency | USB \u0026 RS-232 | SNMP Optional","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eVertiv Liebert GXT MT+ CX GXT-3000MTPLUSC230\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3000VA \/ 2700W online double-conversion UPS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designed to provide reliable, clean, and uninterrupted power protection for mission-critical IT and electronic equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFeaturing an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIGBT-based rectifier, DSP control technology, active input power factor correction, wide input voltage tolerance, pure sinewave output, automatic frequency conversion, and advanced monitoring capabilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, it is designed for applications where stable power and business continuity are essential.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts compact transformer-free design makes it suitable for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eservers, data networks, compact data centers, voice networks, process automation equipment, and other critical systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e operating in environments with unstable or poor-quality mains power.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e3000VA \/ 2700W Capacity\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe UPS provides a rated capacity of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3000VA \/ 2700W\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.9 output power factor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it suitable for demanding IT and electronic loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTrue Online Double-Conversion\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Liebert GXT MT+ CX uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etrue online double-conversion technology\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to continuously regulate incoming power and provide consistent output power to connected equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 3kVA model achieves up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e90% efficiency in AC mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIGBT Rectifier \u0026amp; DSP Control\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIGBT-based rectifier\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combined with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDSP control technology\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides efficient power conversion and precise UPS operation for improved performance and reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eActive Input Power Factor Correction\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActive input power factor correction provides an input power factor of up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.99 at nominal input voltage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping improve the efficiency of the overall power system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWide Input Voltage Range\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe UPS is designed to operate under challenging power conditions with a wide input voltage tolerance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe standard model supports low-line transfer thresholds based on load percentage and ambient temperature, making it suitable for environments affected by voltage fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eGenerator Compatible\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA wide input frequency range of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40Hz–70Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e allows compatibility with generator-based power systems and unstable utility sources.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePure Sinewave Output\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe UPS provides a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epure sinewave waveform in battery mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it suitable for sensitive IT equipment and electronic loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eConfigurable Output Voltage\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOutput voltage can be configured to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e208VAC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e220VAC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e230VAC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e240VAC\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe UPS also features a built-in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50\/60Hz automatic frequency converter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Capacity is derated to 80% when operating in frequency converter mode or when the output voltage is adjusted to 208VAC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eZero Transfer Time to Battery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe transfer from AC mode to battery mode is specified as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ezero\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping maintain continuous power to connected equipment during utility interruptions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eAdvanced Overload Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe UPS provides multiple overload protection thresholds:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e105%–110%:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Shutdown after 10 minutes in battery mode or transfer to bypass when utility power is normal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e110%–130%:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Shutdown after 1 minute in battery mode or transfer to bypass when utility power is normal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e≥130%:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Shutdown after 3 seconds in battery mode or transfer to bypass when utility power is normal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eLow Harmonic Distortion\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe UPS provides:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e≤3% THD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with linear loads\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003e≤6% THD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with non-linear loads\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3:1 current crest ratio\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e supports loads with higher peak current requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertiv\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLiebert GXT MT+ CX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGXT-3000MTPLUSC230\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUPS Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOnline Double-Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCapacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3000VA \/ 2700W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Power Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.9\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRectifier\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIGBT-Based\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDSP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Power Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥0.99 at nominal voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Frequency Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40Hz–70Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Phase with Ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Line Transfer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300VAC ±5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHigh Line Comeback\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e290VAC ±5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e208 \/ 220 \/ 230 \/ 240VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage Regulation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±1% in Battery Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSynchronized Frequency Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e47–53Hz or 57–63Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Mode Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz ±0.5% or 60Hz ±0.5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWaveform\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePure Sinewave\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC Mode Efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 90%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Mode Efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 88%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTransfer to Battery\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZero\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInverter to Bypass\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4ms typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCrest Ratio\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3:1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTHD Linear Load\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤3%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTHD Non-Linear Load\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤6%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVRLA 12V \/ 9Ah\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecharge Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 hours to 90% capacity, typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharging Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0A maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharging Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e82.1VDC ±1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManagement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSmart RS-232 \/ USB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOptional Management\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSNMP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20–90% RH, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNoise Level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 45dBA at 1 meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e421 x 190 x 318 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e27.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, RoHS, WEEE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eInput Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe UPS is designed for environments with unstable mains power and supports an input frequency range of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40Hz–70Hz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eLow-Line Transfer\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe low-line transfer thresholds vary according to load percentage:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e180VAC ±5% at 100%–80% load\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e160VAC ±5% at 80%–70% load\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e140VAC ±5% at 70%–60% load\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e120VAC ±5% at 60%–0% load\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese specifications are based on an ambient temperature below 35°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eLow-Line Comeback\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe corresponding low-line comeback thresholds are:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e195VAC ±5%\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e175VAC ±5%\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e155VAC ±5%\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e135VAC ±5%\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eHigh-Line Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh-line transfer: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e300VAC ±5%\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHigh-line comeback: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e290VAC ±5%\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis wide operating range helps reduce unnecessary battery usage during moderate utility voltage fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOutput Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe UPS provides regulated output power with selectable output voltage of:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e208VAC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e220VAC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e230VAC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e240VAC\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIn battery mode, output voltage regulation is maintained within \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e±1%\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBattery-mode frequency is regulated to:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e50Hz ±0.5%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e60Hz ±0.5%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe output waveform in battery operation is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epure sinewave\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eBattery System\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe standard GXT-3000MTPLUSC230 uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esix 12V \/ 9Ah VRLA batteries\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBattery Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVRLA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12V \/ 9Ah\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Batteries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharging Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0A maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharging Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e82.1VDC ±1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRecharge Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 hours to 90% capacity, typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eTypical Battery Runtime\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eLoad Level\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eRuntime\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e25% Load\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e50% Load\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e75% Load\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e100% Load\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eActual runtime may vary depending on load, battery condition, temperature, and operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIntelligent Management \u0026amp; Monitoring\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe UPS provides integrated monitoring through its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUSB and RS-232 communication ports\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOptional management features include \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edry contacts and an SNMP management card\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eSNMP Management\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe optional SNMP management card enables remote UPS monitoring through an RJ45 network connection and provides capabilities such as:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eRemote UPS monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWeb-based management\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManagement of multiple UPS systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReal-time UPS data\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEvent logs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWarning notifications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAudible alarm notifications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNetwork-based management\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eSelf-Diagnosis \u0026amp; Protection\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBuilt-in self-diagnosis and protection functions help safeguard connected equipment during abnormal mains conditions and battery discharge.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe system can support automatic shutdown of connected client terminals or servers under abnormal power conditions or when batteries become over-discharged.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eExtended runtime can also be supported by adding additional battery resources through the appropriate configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eEfficiency\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe GXT MT+ CX provides the following specified efficiency levels for the 1–3kVA standard models:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eOperating Mode\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003e3kVA Efficiency\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 90%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 88%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe high-frequency, transformer-free architecture contributes to a compact design while maintaining the required power protection functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eConnectivity \u0026amp; Management\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStandard management interfaces include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eUSB\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRS-232\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOptional management interfaces and functions include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSNMP\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDry contacts\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNetwork-based remote monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis enables the UPS to integrate with IT environments requiring centralized power monitoring and management.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003ePhysical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 3kVA standard model measures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003e421 x 190 x 318 mm (D × W × H)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNet weight is approximately:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003e27.6 kg\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compact footprint makes it suitable for applications where reliable UPS protection is required without the larger footprint of higher-capacity systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOperating Environment\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe UPS is designed for operation under the following environmental conditions:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20–90% RH, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNoise Level\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt;45dBA at 1 meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eCertifications \u0026amp; Compliance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Liebert GXT MT+ CX standard model complies with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCE\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoHS\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWEEE\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe GXT MT+ CX is designed for a range of mission-critical and edge infrastructure applications, including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMid-range Windows and Linux servers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eData networks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWi-Fi applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSmall data center rooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVoice networks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCellular sites\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVoice over IP (VoIP)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVSAT systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePBX and IT-enabled PBX systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial automation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProgrammable Logic Controllers (PLC)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eATM systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProcess automation equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMicro-control rooms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEdge infrastructure\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eIdeal For\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eServers and network equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSmall data centers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCorporate IT infrastructure\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNetwork and communication systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTelecom applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial automation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMission-critical systems\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOffices with unstable mains power\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGenerator-supported environments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEquipment requiring pure sinewave backup power\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose Vertiv Liebert GXT MT+ CX 3000VA?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGXT-3000MTPLUSC230\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3000VA \/ 2700W capacity, true online double-conversion technology, 0.99 input power factor, pure sinewave output, wide input frequency tolerance, zero transfer to battery, advanced overload protection, USB\/RS-232 management, and optional SNMP monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in a compact UPS platform. It is designed to provide dependable power continuity for critical IT, networking, communication, and automation equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eMustafa Computers – Authorized Vertiv Reseller in Pakistan\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eMustafa Computers is an Authorized Vertiv Reseller in Pakistan\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, offering genuine Vertiv products with competitive pricing, applicable manufacturer warranty support, and professional pre-sales and after-sales assistance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Buy from Mustafa Computers?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eMustafa Computers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e offers genuine and original products sourced through trusted and authorized channels, backed by competitive pricing and professional pre-sales and after-sales assistance. With years of experience in technology retail and solutions, we provide reliable customer service and applicable manufacturer warranty support for a dependable purchasing experience.\u003c\/span\u003e\u003c\/p\u003e","brand":"Vertiv","offers":[{"title":"1 YEAR VERTIV DIRECT LOCAL WARRANTY","offer_id":50529770995993,"sku":"GXT-3000MTPLUSC230","price":179000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0874\/3577\/2185\/files\/VERTIVLiebertGXTMT_CX3000MTPLUSC230-3KVA2.7KW230VUPSWITHBATTERY.jpg?v=1733448744","url":"https:\/\/mustafacomputers.pk\/products\/vertiv-liebert-gxt-mt-cx-gxt-3000mtplusc230-ups-3000va-2700w-online-double-conversion-pure-sinewave-0-99-input-power-factor","provider":"MUSTAFA COMPUTERS","version":"1.0","type":"link"}